A pitched roof sheds rain by its slope. A flat roof has little slope to help, so anything that pierces it needs a defence of its own. For a skylight, that defence is the kerb: a raised upstand around the opening that lifts the frame and glass clear of the roof surface and gives the waterproof layer something to rise against.
This guide describes how a rooflight is fitted to a flat roof in the order the work goes, then the places where one lets water in, the energy figures, the permissions and escape rules, and the cost figures other guides publish. It is written for a house or extension with a flat roof. A pitched-roof window has its own page in our roof windows and skylights section.
Terms are explained as they come up. A membrane is the waterproof sheet or coating across the flat roof, an upstand is any part of it that rises against a wall or a kerb, and a fall is the slope built into a flat roof so that water drains to an outlet.
What a kerb is and why flat roofs need one
A kerb is a short frame, usually timber or a manufactured unit, fixed around the opening in the roof deck. The rooflight sits on top of it, and the roof's waterproof layer is carried up the outside of the kerb. Without one, the join between glass and roof would sit at the same level as any water lying on the surface.
That is the point of the height. Even a well-built flat roof may carry a little water after rain, and a kerb keeps the join above it. The gap between the glass and the membrane is where leaks begin, so the kerb is where the workmanship counts. Its height is set by the maker's instructions for the unit, which is why the data sheet is read before the opening is cut.
The fall matters as much as the kerb. NFRC reports that BS 6229:2025 asks for a minimum finished fall of 1:80 on membrane flat roofs, and IKO adds: "To achieve a 1:80 fall, the code of practice says that the roof should be designed for a fall of 1:40". A roof that is flatter than designed leaves water standing at the kerb.
Two practical points follow. A kerb added to a roof with poor drainage does not cure the ponding, and a rooflight added to a roof near the end of its life lets the kerb outlast the membrane around it. The roof around the opening is therefore inspected as part of the same visit, not after it.
How a flat roof rooflight is fitted
The sequence varies with the make of unit and the build-up of the roof, and the maker's instructions govern the detail. In outline, a fitting runs like this:
- The survey confirms the roof's structure, the position of joists and the route of any wiring or pipes under the deck.
- The opening is cut and the joists around it are framed to carry the kerb and the weight of the glass.
- The kerb is fixed and insulated, so that the opening does not become a cold spot.
- The membrane is dressed up and over the kerb, in one run where the product allows and with sealed joints where it does not.
- The rooflight is fixed to the kerb and its weathering parts are fitted over the membrane edge.
- The inside is finished with a lining that carries light down into the room.
The maker's instructions set the order of work and the size of the opening, and the kerb is built to match the unit, not the other way round. Each step affects the next. A kerb that is not square leaves the glass with an uneven seat. A membrane that is cut too tight at the corner has no spare to fold into the angle. The finishing at the top edge is where most of the care sits, because the top edge is the part that has to shed water onto the membrane.
Ask how the opening will be kept covered between the cut and the final seal, because the room below is exposed during that gap.
Where a flat roof rooflight lets water in
Leaks around a flat-roof rooflight trace back to a short list of places. Each shows from inside as a stain on the lining or the ceiling nearby. Check the lining at each corner of the well: a mark at one corner points at the kerb corner above it, while a mark all round points at condensation or a failed seal at the frame.
- the corners of the kerb, where the membrane has to bend through two directions at once;
- the top edge of the membrane, where a seal or a cover strip has opened;
- a kerb that stands too low, so that water pooling beside it rises to the joint;
- a join between the kerb and the glass frame that was closed with sealant alone;
- ponding on the roof around the unit, where the fall has been lost.
A bead of sealant is a stop-gap in each of these cases. It covers a gap but does not change the route the water takes, and the next movement of the frame opens it again. The repair that holds is the one that restores the upstand, the dressing or the fall.
Not every wet patch is a leak. A cold pane in a warm room collects droplets on the inside, and the water can run down the frame and look like a drip. Our answer on condensation on a roof window explains how to tell them apart, and our post on why roof windows leak covers more of the causes. For a window being swapped, replacing a Velux window sets out the steps.
The seam between glass and roof can only be as dependable as the upstand beneath it.
Energy figures and which category a unit falls in
Approved Document L Volume 1 sets limiting U-values for new fabric elements in existing dwellings, in Table 4.2 of the 2021 edition. The edition applies until 24 March 2027, when the 2026 edition replaces it for work other than higher-risk building work.
| Element | Figure | Note |
|---|---|---|
| Roof window | 1.4, or Window Energy Rating Band B | Takes the window figure |
| Rooflight | 2.2 | Rooflights only |
The distinction matters because a roof window takes the window figure, and 2.2 applies to rooflights only. Which category a given product falls into is set by the maker's data sheet, so ask for it in writing before the order is placed. The roof around the unit is judged separately, because a thermal element "means a wall, floor or roof (but does not include windows, doors, roof windows or roof-lights)". Ask for the product's declared figure in writing, and for its Window Energy Rating where Band B is the route.
That roof is judged under Table 4.3 if it is renovated: Approved Document L 2021 includes "Replacing the waterproof membrane on a flat roof" in renovation. Where "More than 50% of the surface of the individual thermal element is renovated", the roof should reach the improved 0.16, where that is feasible and pays back within 15 years; the table's 0.35 is the threshold for a retained roof.
A dressing around one kerb is a small part of a roof, and building control confirms where the line falls on your own roof.
Permissions, escape windows and who checks
On a house, Class C of the permitted development order covers alterations to the roof, with limits on how far an alteration may stand proud of the roof and how high it may reach. A kerbed rooflight stands higher than a flush one, so check those limits before ordering. Our planning guide for roof work sets out the wording. A flat is not a dwellinghouse under the order, so Class C rights do not cover it.
Class C has no article 2(3) exclusion, so a conservation area does not remove it, but an Article 4 direction can withdraw further rights and the council confirms whether one covers your street. Listed homes keep their permitted development rights, but listed building consent is needed for work "in any manner which would affect its character as a building of special architectural or historic interest".
Building Regulations are a separate step. Arun District Council's building control page lists "replacing roof coverings on pitched and flat roofs" among alterations that need approval, so Arun addresses go through that council's building control before the work. Havant addresses go through your building control body. Cutting joists to form the opening is a structural change, so the new framing is designed to carry the load, and the route is confirmed first.
Escape is a different matter again. AD B asks an escape window to have a minimum area of 0.33 m2, a minimum height and width of 450mm each, and an openable area whose bottom edge is a maximum of 1100mm above the floor. Escape windows serve storeys up to 4.5 m above ground, so a rooflight is not assumed to be one.
What third-party guides report for cost
Published prices for rooflights describe typical jobs. They help to judge a quote and say nothing about your roof, and none of the figures below prices a kerb, a membrane dressing or the work inside the room.
- MyJobQuote gives "Average cost for a standard mid-range Velux window is £1,100." Its page was updated on 22 September 2026 and states no VAT basis.
- The same guide puts a straightforward swap at "around £100 less", because the opening is already in place.
- Checkatrade (June 2026) lists rooflight replacement, such as a Velux, as "from £1,000" in its repair-rate table. "From" is the start of a range, and its table says costs exclude VAT and access equipment.
A new rooflight on a flat roof is not a swap. It needs an opening cut, a kerb built and a membrane dressed around it, and the roof beneath checked for fall and condition. None of that is in a single headline figure.
The things that move the total are the size of the unit, the glazing specification, the kerb, the condition of the surrounding roof, the lining inside and the access. We do not multiply a rate into an estimate. What follows the survey is a single written total, with scaffold in it. When comparing, see whether each quote states VAT and the scaffold. Use the figures for scale only, then ask for a total that names the unit, the kerb, the dressing and the lining.