Roof window condensation

Why is there condensation on my roof window?

The short answer

Condensation forms when moist room air meets glass or a frame colder than that air, so beads on the room-facing side point to moisture in the room and not to a leak. Mist locked between the two panes is a separate fault: the unit's edge seal has gone. Damp that arrives only with rain, at the lining under the frame, indicates a worn sash seal or flashing that has lifted. The three are told apart before anything is repaired.

Wet glass has three possible causes, and the repair differs for each. Separating room moisture from a failed seal or a leak decides what, if anything, gets done.

Roof lantern on a single-storey brick kitchen extension

Why the glass is the first place to show it

Air indoors carries water vapour, and warm air holds more of it than cool air. When that air touches a cold surface, some of the vapour turns back into drops. Glass is thin, so it tends to be among the coolest surfaces in a loft room, and a roof window can be where the drops show first.

Everyday life adds to the vapour in the room:

  • Breathing and sleeping, in a loft bedroom as in any other.
  • Cooking, washing and bathing, with the steam drifting upstairs.
  • Clothes drying indoors on a rack or a radiator.
  • A shut window and no open vent for long stretches of the day.

BS 5250:2021 sets out how moisture in buildings is managed, and a roof window is only one part of that picture. A new window on its own does not cure moisture that the room keeps producing.

Beads that appear on a cold morning and have cleared by midday are one thing. A stain that is still there in dry weather is another.

Telling condensation from a failed seal or a leak

Look at the glass from inside, in daylight and again while it is raining. The table sets out the sign, the place it shows and what it points to.

Three kinds of wet on a roof window
SignWhere it showsWhat it points to
Beads that wipe awayRoom-facing glass or frame, running to the sillMoisture in the room air
Mist that cannot be wipedBetween the two panesA failed edge seal on the unit
Damp that comes with rainLining below the frame, or a ceiling stain some way belowA worn sash seal, or flashing at the frame edge

A hose test sorts the last two. The glass is wetted first, the frame next and the flashing last, with someone indoors watching. Please stay off the roof when you test it for yourself.

The last row is the one to act on promptly, because damp that arrives with rain is water getting in. A note of the date and the weather each time it appears helps the survey. Our answer on condensation or a roof leak covers the same question for the roof as a whole.

What lowers it indoors

The cure is to lower the vapour in the room or give it a way out, and none of it needs tools.

  1. Open the window's vent, or the sash itself, for a while each morning, so the damp air leaves.
  2. Use an extractor fan or an open window where you cook and bathe, and keep the door to that room shut while you do.
  3. Dry washing outside or in a room with an extractor, and not on a rack in the loft bedroom.
  4. Wipe the beads off the sill so they do not soak into the lining, and wring the cloth out rather than leaving it on the ledge.

The roof space can play a part as well. Marley's figures for a cold roof lined with a high-resistance underlay, which is not vapour-permeable, are 25 mm of eaves ventilation at pitches of 15° or less and 10 mm above 15°. Whether yours has that ventilation is a matter for the loft inspection, and it concerns the roof as a whole and not the window itself.

A new unit does not fix a damp room. If the beads come back after any repair, the moisture source is the next thing to look at, and airing the room is the first thing to try.

When a survey is worth having

Beads that clear are a household habit to adjust. These are the signs that something more is going on, and each one is worth a visit.

  • Mist inside the glazing that never clears, a sign the unit's seal has failed.
  • Dark spots or mould on the lining or the timber round the frame.
  • A damp line along the foot of the lining, or a ceiling stain somewhere beneath the window.
  • Water at the frame edge only when rain is driving at the sash.

Inside, the survey reads the frame, the lining and the timbers. In the loft it checks the underlay and the flashing at the edge of the opening. It tells you which of the three it is, with photographs, before anything is priced.

If the answer is the unit, our answer on reglazing a Velux window covers when a new glazing unit is enough. If the flashing is at fault, the repair is to the roof and not to the window. Our roof windows and skylights page describes the service, and a written total follows the survey.

Related questions

Does condensation mean my roof window needs replacing?

Not by itself. Beads on the room side that wipe away are the room's own moisture condensing, and a new window would meet the same air. Mist between the two panes shows the unit's seal has failed, and that can be put right by reglazing or replacing. The survey separates the two first.

Why does the roof window mist when the walls stay dry?

Glass is thin, so it tends to be among the coolest surfaces in the room, and vapour in the air turns to drops on the coolest surface it touches. A wall holds more warmth. Airing the room and using the vent, together with a fan where you cook and bathe, lowers the amount of vapour.

Where's the water showing?