023 9396 0313 Get a written quote

Roof window or skylight

What is the difference between a roof window and a skylight?

The short answer

In everyday use the words overlap, but the Building Regulations draw a line. AD L 2021 gives roof windows the window figure of 1.4 W/m²K, or Band B on the Window Energy Rating scale, while rooflights get a separate figure of 2.2 W/m²K. A roof window is a glazed opening placed in a pitched slope. Skylight is the everyday word, and the supplier should say which category a unit belongs to.

The two words are used loosely, yet the Building Regulations treat roof windows and rooflights as different things with different figures. The category decides the energy limit.

An old brick workshop with a corrugated cement sheet roof and two rooflights

Two names, two rows in the energy table

Approved Document L is the Part L guidance for dwellings in England. Its Table 4.2, headed "Limiting U-values for new fabric elements in existing dwellings", gives limits for the glazed parts of a roof, and AD L 2021 applies until 24 March 2027, when the 2026 edition takes effect for ordinary building work.

Glazed roof elements in AD L 2021 Table 4.2
ElementLimit
Rooflight2.2 W/m²K
Window (roof windows included)1.4 W/m²K, or the minimum of Band B on the Window Energy Rating scale

The window row has a footnote reading "Including roof windows and curtain walling". The Building Regulations, in defining a thermal element, list "windows, doors, roof windows or roof-lights" as separate items, so the two terms are not interchangeable in law. A quote that uses one word for both products leaves the figure unclear, and it is worth asking it to be rewritten.

Each row is a limit for new elements, and the product's own figure has to match it or beat it. Our guide to roof window energy rules sets out the tables in full, with the renovation rules for the roof around the glass.

How the two are used on a roof

On a pitched roof the product people usually mean is a roof window: a frame fixed to the rafters, a sash that opens, and a flashing kit that leads rain round it and back onto the covering. A Velux is a maker's name for this kind of window.

A rooflight in a flat roof or an extension is a different construction. It sits on a kerb, a raised upstand round the opening, and the roof covering is dressed up to the kerb and not around a sloping frame. Our guide to flat roof skylights and kerbs covers that work.

  • Roof window: placed in the slope, flashed to the covering, judged on the window row.
  • Rooflight on a flat roof: set on a kerb, waterproofed with the roof covering, judged on the rooflight row.

The names blur in shops and in price guides. Checkatrade, for example, lists "Rooflight replacement (e.g. Velux)", using a maker's roof window as its example. That is a reason to ask the supplier which category the unit is sold as, and not to rely on the product name or on the word skylight.

Why the category changes the figure

The rooflight limit of 2.2 W/m²K is looser than the 1.4 W/m²K set for a window, so a product can pass under one row and miss under the other. That makes the label on the order matter. A unit sold as a roof window is judged on the window row, and one sold as a rooflight on the rooflight row.

Three things to get in writing from the supplier:

  1. Whether the maker sells the unit as a roof window or as a rooflight.
  2. The figure stated for the size you are ordering, given either as a U-value or as a Window Energy Rating band.
  3. Where the maker's paperwork for the unit can be inspected, should building control ask.

Building control is carried out by the council's building control team or by a registered building control approver, and the question of how the table applies to your job goes to it. Our answer on building regulations for a new roof window sets out the route.

File the data sheet with the invoice, since it carries the figure that matters.

Which suits your roof, and what comes next

The roof decides the answer more than the word does. A pitched roof with loft space to light suits a roof window placed in the slope. A flat roof, or a flat-roofed extension, suits a rooflight on a kerb. The survey looks at the covering, the pitch and the timbers, and says which fits.

Either one is a change to the roof, so the planning side is a separate check. Listed homes, conservation areas with Article 4 directions and flats each change the answer, and our planning guide works through the tests.

Before an order goes in, settle three things: which category the unit belongs to, which figure the maker states for it, and which building control body is to be asked about the route. They take a phone call each and save a disputed delivery later.

The price comes to you as a single sum, written after the survey visit. Ask it to name the category and the figure, and to say if scaffold and VAT are counted in it. The wider service is described on our roof windows and skylights page.

Related questions

Is a Velux a roof window or a skylight?

Velux is a maker's name. A window with an opening sash set into a pitched slope is a roof window, and price guides and shops often call such windows skylights or rooflights as well. The Building Regulations treat roof windows and rooflights separately, so ask the supplier which category the unit is sold as.

Which energy figure applies to a skylight?

It depends on the category. In AD L 2021 Table 4.2 a roof window takes the window row, 1.4 W/m²K or Window Energy Rating Band B, and a rooflight has its own row at 2.2 W/m²K. Ask the supplier to state the category and the figure for your size, and keep the data sheet.

Where's the water showing?

You'll get one written total price.

10-year workmanship guarantee, in writing

Get a quote Call WhatsApp