Two places insulation can go
Foam did two jobs at once, forming the insulation and lining the roof slope. Taking it out separates them, so the first decision is where the new insulation will sit.
- At ceiling level, laid between the joists and over them, so the loft above stays cold and ventilated.
- Along the roof slope, between or under the rafters, if the loft is used as a room.
A cold loft keeps the structure above the insulation at roughly the temperature of the outside air, and it needs air to move through it, so the eaves must not be blocked by insulation or by anything stored against them. A warm roof insulated along the slope changes the make-up of the whole roof, and its underlay and any air path have to suit the layers beneath.
Neither suits every house. If the loft is a store and nothing more, insulating at the ceiling is the simpler arrangement. If it is a bedroom or an office, the slope has to be insulated, and the underlay then matters more. We tell you which we would recommend for your roof and why, after the survey. That view concerns the building and how you live in it, and it makes no claim for any product.
What Part L asks for in England
Insulating a roof again can bring in AD L 2021, the edition in force until 24 March 2027, when AD L 2026 takes over for England. Table 4.3 gives two figures for a roof that already exists:
| Column | Meaning | W/m²K |
|---|---|---|
| (a) | Threshold | 0.35 |
| (b) | Improved | 0.16 |
When renovation covers more than 50% of the roof's surface, the guidance wants the entire roof brought to column (b). Paragraph 4.13 allows for the case where the improved figure cannot be reached, and it ties the fallback to a simple payback of no more than 15 years.
These are the targets the work is measured against, so the survey records what share of the roof is affected before anything is specified, along with the roof's current construction. Your building control body can then say how the figures apply to your house. A loft that is being converted is a separate case with its own rules, and it is worth telling us at the start if that is what you have in mind.
Underlay, air and moisture
New insulation has to suit the layer outside it. Roof underlays differ: some let water vapour through and others do not, and a high-resistance underlay is not the same thing as a breathable one. Where the underlay needs ventilation, the insulation must leave room for it, and the eaves should be checked for blockage at the same time.
With a high-resistance underlay in a cold roof, Marley gives 25 mm of eaves ventilation at 15° or less and 10 mm above 15°. That is the manufacturer's figure, to be checked against the data sheet for the product actually fitted.
The Energy Saving Trust's remark that closed-cell foam is "not vapour permeable" shows why moisture deserves care here. The same thinking applies to whatever replaces the foam: the layers are chosen together, not one at a time, so that a new sheet or a new quilt does not trap what the old foam trapped.
Our guide to re-felting after spray foam removal takes the underlay decision further, and a read through it will help you ask better questions of anyone who quotes.
Choosing, and getting it in writing
The decision comes after the foam is off and the timber has been checked, since what the structure and the underlay need can alter the plan. If a rafter has to be reinforced or the felt renewed, that is done first, and the insulation goes over finished work, so the timber is never closed in before it has been seen and photographed.
Ask for the choice in writing with its reasons: where the insulation sits, what lies above and below it, and what ventilation is kept. Ask the same of any other quote, and check that each one states VAT and scaffold.
You may wonder whether foam could simply go back. It could, but ask your mortgage provider first, because RICS reported concern in some parts of the lending market in March 2023. Our answer on spray foam and mortgages sets out the lending position, and the spray foam insulation removal page shows the whole job.
The written price is a single total, and it covers the insulation as well as the removal.