023 9396 0313 Get a written quote

Flashing kits

What is a flashing kit on a Velux window, and which do you need?

The short answer

A flashing kit is a ready-made set of pieces that fits round a roof window frame and leads rain past it and back onto the roof covering. You need the kit made for your covering, such as profiled tile, plain tile or slate, and sized to the window. The survey notes the covering, the depth of its profile and the pitch of the slope before anything is ordered.

The kit is what joins a roof window to the covering around it. Which one you need follows from the covering, its profile and the pitch of the slope.

An old brick workshop with a corrugated cement sheet roof and two rooflights

What the kit does at each edge of the frame

A roof window frame has four edges, and the kit gives each one its own piece.

  • Head: the top edge, which takes whatever the slope above delivers and turns it left and right.
  • Sides: long pieces that guide the water past the frame while keeping it on the surface of the metal.
  • Foot: the apron, which hands the water back to the covering underneath and has to lie close to it.
  • Corners: the joints where one piece meets another, which a careless cut can leave open.

The pieces overlap each other, and the covering laps over their edges, so every lap sheds water outwards. A lifted apron can be hard to see from below, and when it fails the signs are a mark on the ceiling beneath the window, or dampness along the lower edge of the lining.

A bead of sealant is no stand-in for a lap. It may fill a hairline gap for a while, and it can cover a missing lap, so ask what lies beneath any bead you are shown.

Because the pieces overlap, the order they go on in matters as much as the pieces themselves, and the survey notes which parts of an old kit have lifted.

Which kit your covering needs

Each kit is made for one family of coverings, since the metal has to follow the shape it meets. A kit meant for slate will not follow a profiled tile, and the mismatch can leave a gap.

What to tell the supplier about each kind of covering
CoveringTell the supplier
Profiled tileThe shape of the tile and how deep its profile stands
Plain tileThat the covering is small flat tiles laid in courses
SlateThat the covering is slate, and the pitch of the slope

Pitch matters on any covering. It narrows the choice of window and kit, and the data sheet for each states its range, so the slope is measured and not guessed.

Daylight photographs of the slope taken from the garden or street let a supplier narrow the choice before anyone goes up. Our answer on a roof window in a slate roof goes further into slate.

If you cannot tell what the covering is, say so, and the survey identifies it. Tiles that look alike from the ground can have different profiles.

Lead flashing, and a kit on an older window

Older windows were sometimes flashed by hand in lead sheet and not with a kit. Royston Lead's brochure sorts lead sheet by code. Code 3, at 1.32 mm, is recommended for lead soakers only, and codes 4, 5 and 6 are listed for flashings. Which code goes where is settled in the specification, and lead work falls within our lead roofing service.

The MyJobQuote lifespan for lead flashing carries two hedges worth keeping: it has to be correctly installed, and the wording is "can last for over 80 years". A lead flashing that is still sound may be kept when a window is swapped, and the quote says which it is.

A new frame in an old flashing inherits that flashing's faults. Three questions settle it before work starts:

  1. Is the metal round the frame new or retained?
  2. Are the tiles or slates beside the frame being replaced?
  3. Is the kit the one made for this covering and this window size?

Where only the flashing has failed, the surround can be lifted and the flashing renewed with a sound window left in place.

Checking the work and the written price

Once the kit is in, each edge can be checked, and you are shown photographs of the work before the covering is laid back over it. Any piece that looks short or sits proud is put right at that point, while the roof is still open. The head and the sides are checked for a lap that sheds outwards, the foot for an apron that lies close, and the corners for gaps. The covering round the frame is then relaid up to the metal.

Our guide to replacing a Velux window sets out the order of work, and the wider service is on our roof windows and skylights page.

The written total should state whether the metal round the frame is new or retained, what is happening to the covering beside it, and whether scaffold and VAT are counted in the sum. It is one price, set after the survey.

The energy figure is a separate matter. Building control is carried out by the council's building control team or by a registered building control approver, and a flashing kit does not alter the figure the window itself has to meet.

Related questions

Can the old flashing be reused on a new window?

It can where the metal is sound and suits the new frame and covering. Otherwise a new frame in an old flashing inherits that flashing's faults. The survey looks at the flashing and the covering round it, and the written total should say whether the flashing is renewed or retained.

Does the pitch of the roof change which kit I need?

Pitch narrows the choice of window and kit, and each data sheet states its range. The covering matters as well, because kits are made for particular coverings. The survey notes the covering, the depth of its profile and the pitch before anything is ordered, and the written total then reflects what was found.

Where's the water showing?

You'll get one written total price.

10-year workmanship guarantee, in writing

Get a quote Call WhatsApp