What the English guidance says about heating
Approved Document L (AD L) is the part of the Building Regulations that deals with energy. It says when a new ground-level extension falls outside its requirements. The 2021 edition took effect on 15 June 2022 for use in England, and its paragraph 0.14 gives five conditions, every one of which has to apply. The fifth reads: "The heating system of the dwelling is not extended into the conservatory or porch."
AD L 2026 replaces it from 24 March 2027, with 24 September 2027 for higher-risk work. Its version says the heating system of the dwelling "does not extend into the conservatory or porch", which is close to the 2021 text. Both are about the heating system of the dwelling and whether the conservatory has been connected to it.
How that applies to a particular room is decided by building control, not by the roofer or the heating engineer. The same paragraph also asks for a ground-level extension of 30 m² or less and Part K glazing, which the energy exemption answer sets out in full.
Why a separating wall or door matters too
Condition (d) of that paragraph says any wall, door or window that separates the extension from the dwelling "has been retained or, if removed, has been replaced with a wall, door or window". Heating and separation therefore work as a pair. A conservatory still divided from the house by a door, with the house heating stopping at that door, sits differently from one opened into the living room and fed from the same radiator circuit.
Because the five conditions are joined by "all", one failure is enough to take the room outside the exemption. These changes would do it:
- A wall, door or window between house and conservatory is removed and not replaced.
- Radiators, underfloor heating or ducting are fed from the house system.
- The floor area comes to more than 30 m².
- The glazing does not satisfy Part K.
Any one of them is a reason to speak to building control before the work starts, and not after it is finished and the room is already in use.
Condition (d) is the one with a remedy built in: a wall, door or window can be put back where one was taken out, and the condition is then met again. Ask building control whether that would be accepted for your room before you rely on it.
Where a new solid roof comes in
A warmer room can mean a solid roof and a heating change planned side by side. The Planning Portal notes: "Many homeowners choose to replace their traditional polycarbonate conservatory roof with a solid tiled roof for better thermal efficiency." It also states the duty: "A new roof must comply with building regulations to ensure it is structurally safe, energy efficient and properly ventilated."
A roof swap and a heating plan are therefore two separate questions, and both go to the same building control body. A covering that is 15 per cent or more heavier needs approval under the Planning Portal's re-roofing test, so the frame is looked at before any tiles are priced.
For what a solid roof does and does not change in winter, read will a solid roof make a conservatory warmer. We confirm the route with building control first, and give one written total price once the roof and its frame have been inspected.
The two questions also run on different timetables. A heating change can be made at any time, while a roof is a one-off build, so it makes sense to settle the heating plan before the roof is specified. A roof designed without that plan can need changes later, at a time when the old one has already gone.
Questions to settle before pipework goes in
A short list keeps a call to building control useful. Have these to hand before you ring:
- The floor area of the conservatory, set against the 30 m² limit.
- Whether the glazing meets Part K, and the material of the roof.
- Whether the wall, door or window between house and conservatory stays.
- How the room would be heated, and where that heat would come from.
- Whether a new solid roof is planned at the same time.
With those answers, building control can say whether the exemption holds and what applies if it does not. If it says the exemption does not hold, ask what it wants to see in its place, and ask for that reply in writing, because it fixes the scope of any heating or roof work that follows.
A survey for our conservatory roofs work looks at the roof, the frame and the wall junction, so the roof side of the question can be settled alongside the heating side. The building regulations guide sets out what building control looks for.