The five conditions in paragraph 0.14
AD L 2021, the edition for England that took effect on 15 June 2022, sets out the exemption for a conservatory or porch added to a dwelling. Every condition has to apply, and the paragraph says so with the words "if all of the following apply".
| Condition | Wording in AD L |
|---|---|
| a | The extension is at ground level. |
| b | The floor area of the extension does not exceed 30m2. |
| c | The glazing complies with Part K of Schedule 1 to the Building Regulations. |
| d | Any wall, door or window that separates the extension from the dwelling has been retained or, if removed, has been replaced with a wall, door or window. |
| e | The heating system of the dwelling is not extended into the conservatory or porch. |
The table repeats the wording of paragraph 0.14, so you can read each condition as it is written. Reading it against your own room takes a few minutes, and the questions it raises are worth settling before any roof is ordered.
The 30 m² limit and the Building Regulations schedule
The Building Regulations 2010 list the same kind of extension in Schedule 2, Class 7: "The extension of a building by the addition at ground level of" a conservatory, porch, covered yard or covered way, "where the floor area of that extension does not exceed 30m2, provided that in the case of a conservatory or porch which is wholly or partly glazed, the glazing satisfies the requirements of" Part K. The schedule is published on legislation.gov.uk.
So 30 m² is a floor area in both documents, and the glazing test is Part K in both. A conservatory over that floor area, or with glazing that fails Part K, is not within the exemption as AD L words it.
The energy exemption and the schedule sit in different documents, and each speaks in its own terms. Building control can say how they meet for one particular extension, which is why the question goes to them and not to a neighbour or a guess.
Floor area is measured on the extension itself, so a conservatory that has been enlarged since it was built needs its present size checked, not the size on the original plan.
What the list says about the roof
None of the five conditions mentions the roof covering. They concern the level, the size, the glass, the separation from the house and the heating. A new roof is a separate point. The Planning Portal states that "A new roof must comply with building regulations", so exchanging polycarbonate for a solid covering is a question for building control before work starts.
A heavier covering raises a structural point as well, and a solid roof can be heavier than the one it replaces. We check with building control first. The conservatory roof building regulations guide covers who inspects what, and the planning answer deals with the separate planning question.
An older conservatory raises the question of which text it was built under, so start by finding out when yours was added, and what drawings or completion papers exist. Those papers can show what the room was built to, and they are worth having ready when you ask building control.
If no papers can be found, say so when you ask. Building control can advise what it needs in their place, and a survey of the conservatory records its size, glazing and separation from the house so the answers to the five conditions are written down.
Checking your own conservatory against the list
Work down the conditions in order and answer each one plainly:
- Is the floor at ground level?
- Is the floor area 30 m² or less?
- Does the glazing satisfy Part K?
- Is there still a wall, door or window between conservatory and house, or a replacement for one that was removed?
- Is the home's heating system kept out of the conservatory?
A "no" at any step means the room is outside the exemption, and building control can say what applies in its place. A run of "yes" answers does not settle the roof, which is judged on its own. For the heating step, see whether the house heating can run into a conservatory. Our conservatory roofs survey measures the room and records the roof, the frame and the junction with the house, and building control makes the decision.
Keep the measurements and photographs together with any papers from when the conservatory was built. Together they let building control answer quickly, and they show the roofer exactly what the new roof has to fit.
Write each answer next to its condition, with the date, so that the same notes can go to building control, to a roofer and, later, to a buyer.