Flat roof falls

Does a flat roof need a fall, and how much?

The short answer

Yes. BS 6229:2025 sets a minimum finished fall of 1:80 for membrane flat roofs, which means a drop of 1 unit for every 80 units of run. A finished roof has to meet that figure after the tolerances of building have taken their share, so the roof is designed to a steeper fall. IKO reports that the code asks for a design fall of 1:40.

Every flat roof needs a slope so that rain leaves it, and the standard sets a minimum. The figure, why design is steeper, and where water travels.

Row of flat-roofed brick lock-up garages with worn felt

What the standard actually says

BSI lists BS 6229:2025 as current and BS 6229:2018 as withdrawn. Its scope is any flat roof, or a curved roof with a pitch not greater than 10 degrees, that uses continuously supported flexible waterproof coverings. That means membranes such as felt, EPDM rubber and GRP fibreglass. Lead sheet roofs lie outside it.

The National Federation of Roofing Contractors says the 2025 edition sets "a minimum 1:80 finished fall for general roof areas and internal gutters". IKO, a membrane maker, says that "the recommended minimum fall for a flat roof is 1:80", and it reports a design fall of 1:40 in the code of practice.

The words finished and minimum both matter. The 1:80 is what the roof should have when it is complete and settled, not what a drawing shows before the work starts, and it is a floor, not a target to aim at exactly. A roof designed to a steeper fall can lose some of it to the deck and the layers laid over it and still finish above the minimum.

From the upstand down to the outlet

A fall only counts if it carries water all the way. Follow a raindrop in the order the roof handles it:

  1. It lands on the covering, or runs down a wall and meets the upstand, the strip of membrane turned up the wall.
  2. It is carried along the deck by the fall, away from the upstand and across the laps.
  3. It reaches the roof edge, or an internal gutter that sits behind a parapet.
  4. It leaves through an outlet, which is meant to be the lowest point of the whole roof.

Each stage depends on the one before. A fall that stops short of the outlet leaves a hollow beside it. An upstand that sits in a dip collects water against the wall, and the water there stands against a joint.

Not every roof is shaped like this. A roof with a parapet on three sides may have an internal gutter doing the last stage of the route, and the survey follows that gutter to its own outlet.

Our guide to flat roof falls and ponding shows how to read a hollow once it has formed, and how much standing water is ordinary.

Gutters and the fall that serves them

The same idea applies to the gutter at the end of the route. BS 6229:2025's 1:80 covers internal gutters, so a gutter set behind a parapet is checked as closely as the deck itself.

An ordinary gutter on the outside is a separate case. Brett Martin, a manufacturer, advises a fall of 1 mm for every 600 mm towards the outlet. That figure belongs to a gutter run and cannot stand in for a roof's own fall, and the two are never added together or swapped for each other. A survey measures the fall of the roof and the fall of its gutter separately, and records both. A gutter that holds water at one end shows the same trouble as a hollow in the deck, on a smaller scale.

Falls and where each one applies
ItemFigureSource
Roof areas and internal gutters1:80 finished minimumBS 6229:2025, via NFRC
Design to reach that finish1:40Reported by IKO
Outside gutter run1 mm per 600 mmBrett Martin

Each figure answers a different question, so a survey asks which one applies to the part of the roof in front of it.

What happens when the roof has no fall

A roof with no fall, or with a fall that has settled away, holds water in hollows. Standing water does not prove a fault, but it is the first thing a survey looks at, along with the lowest point and whether an outlet sits there.

The remedy depends on how far the fall is out. A small shortfall in one corner is a different job from a roof with no fall anywhere, and the survey says which one yours is.

Re-covering over the same shape keeps the same water, so only a change to the fall changes the result. New falls are set into a new deck or a layer of tapered insulation, which is why the fall is settled ahead of the choice of covering.

Re-laying a fall can change the finished height at a door sill or a wall, and it can bring Part L into the job. The renovation rules of Part L reach a flat roof when its membrane is replaced (AD L 2021 para 11.2(d)), which our answer on flat roof regulations explains. Our flat roofing page covers the wider work, from a single repair to a new roof.

Related questions

Does the 1:80 figure apply to every flat roof?

It applies to membrane roofs under BS 6229:2025, meaning continuously supported flexible waterproof coverings on roofs with a pitch not greater than 10 degrees. Lead sheet roofs are outside that standard, so their falls follow other guidance. A survey identifies which applies to your roof.

Why is a flat roof designed steeper than the 1:80 minimum?

BS 6229:2025 sets the minimum on the finished roof, so the design allows for tolerances in the deck and the covering. IKO reports a design fall of 1:40 in the code of practice. A roof designed at the bare minimum could finish below it and hold water.

Where's the water showing?