023 9396 0313 Get a written quote

Tile fixings

Do roof tiles need to be nailed or clipped?

The short answer

Yes: tiles are held by a fixing specification, not left to rest in place. BS 5534 sets out how slating and tiling is done and how the fixing specification is worked out. It is a code of practice, not law, and Marley says mortar alone can no longer be relied on as the only means of securing the roof covering.

Tiles are fixed to a specification worked out for the site, not left to sit on their own weight. What the code says and what it is not.

Edwardian brick villas with clay tile roofs and decorative ridges

What BS 5534 covers, and what it is not

BS 5534 is the British Standard dealing with slating and tiling of pitched roofs and vertical cladding, and BSI lists the current edition as BS 5534:2014+A2:2018. A code of practice is advice on how work should be done, written by people in the industry. It is a different kind of document from an Act or a regulation.

Marley, a tile maker, states it plainly: installing to BS 5534 isn't required by law. That does not make the standard irrelevant to a working roofer. Surveyors and tile makers read a fixing job against it, and a roofer who sets it aside has no recognised yardstick to offer when a tile lets go.

Do not confuse the code with the Building Regulations, which are law and carry their own tests for roof work. The two sit side by side. We read BS 5534 for how a covering is fixed, and we confirm the Building Regulations route with your building control body before a re-roof begins, so the finished roof is both compliant and properly held down.

Nails, clips and the fixing specification

Which tiles take a nail, which take a clip and which take both is settled by the specification, and the specification belongs to the roof. Marley lists what BS 5534 contains, and the list shows why one rule for every house cannot exist: "batten selection, methods of fixing, wind uplift formulas and a means of calculating fixing specifications."

  • the battens are chosen first, because they carry the tiles
  • the method of fixing is picked from the maker's options
  • wind uplift is calculated, not assumed
  • the result is a fixing specification for that roof

Exposure is one input. Cupa, a slate maker, says: "Buildings positioned on slopes, hills or coastal areas as well as tall buildings will be graded with higher exposure." Coastal homes are graded for higher exposure, so the fixing specification is calculated for the site under BS 5534.

What we do is work through the roof in front of us, reading the maker's data sheet for the tile and applying the code for the method. The same data sheet gives each tile's minimum pitch, a related check explained in our guide to roof pitch and tile choice.

Why mortar by itself fell out of favour

Ridge and hip tiles on older roofs may be bedded on mortar and nothing else. Marley says the amendments to BS 5534 made it clear that mortar "could no longer be relied upon as the only means of securing the roof covering", and its dry-fix page says "the tensile strength of mortar alone could no longer be relied upon". Marley dates the change two ways on different pages, so no year is given here.

The weight of that sentence sits on the word only. Mortar can remain part of a detail, as a bed or a seal along the ridge. The code asks that something mechanical holds the tile too, so a failed bed does not release it. Mortar that has cracked and crumbled calls for a look at the ridge, and a ridge held by mortar alone raises a fixing question as well as a mortar question.

No ridge needs to be torn off in a panic. The point is reliance. A repair that re-beds the same tiles in fresh mortar repeats the arrangement the code moved away from, which is why we look at what holds the tile before deciding what to redo.

Ridge and hip tiles take their own standard

Ridge and hip tiles sit along the top and the angles of the roof, where the wind has the easiest purchase, so they have their own rules. Marley says BS 5534 requires mechanically fixed ridge and hip tiles. BS 8612:2018 is the specification covering dry-fixed ridge, hip and verge systems, and BSI shows it as current.

Dry fix means the tiles are held by clips, screws or a purpose-made system rather than a continuous mortar bed. It is another way of making the same joint, and it needs components that suit the tile and the roof.

At a survey we look at how each ridge and hip is held, and report whether it needs re-fixing, a mechanical fixing added or no work at all. The job, and a single written price, follow from that. Where tiles are lifted for the work, the battens beneath get looked at too, since a fixing needs sound timber to hold it.

For the wider context, see our pitched roofing page, and our guide to common pitched roof problems covers what a loose ridge tile can let in.

Related questions

Is a roofer breaking the law by not following BS 5534?

Marley says installing to BS 5534 isn't required by law, because it is a code of practice. It is still how a fixing job gets judged in practice, and mortar cannot be the only thing holding a tile. Ask which standard a quote follows and how the fixings are specified for your roof.

Does a house near the harbour need different tile fixings?

Cupa says a tall building, or one on a slope, a hill or in a coastal area, is graded with higher exposure, and BS 5534 ties the fixing specification to the site. We work from the code and the data sheet for your roof, so a house near the harbour gets the specification its own site calls for.

Where's the water showing?

You'll get one written total price.

10-year workmanship guarantee, in writing

Get a quote Call WhatsApp