Soffit ventilation

Do soffits need vents when they are replaced?

The short answer

A soffit needs a vent where the roof above takes its air at the eaves, which is the position for a cold roof laid with high-resistance (HR) underlay. Marley gives "25mm along the length of the eaves for pitches of 15° or less; 10mm along the length of the eaves for pitches of more than 15°". A roof whose air-permeable underlay sits above a well-sealed ceiling can manage on normal eaves construction. Work out which roof you have before the old boards come off.

A soffit is the board fixed beneath the roof's overhang, and on some roofs it is also where air gets in. How to tell which kind you have.

A blocked uPVC gutter overflowing with rainwater after a storm

What a vent in the soffit is doing

The soffit is the board fixed under the overhang of the roof, between the wall and the back of the fascia. On some roofs it does more than tidy the eaves. A cold roof is one where the insulation lies along the loft floor, so the roof space above it stays cold. Moist air from the house can rise into that space, and unless it is carried away it can settle on the underside of the roof covering.

Marley's guidance on cold roofs, which follows BS 5250, handles this by letting air in along the eaves. Outside air enters at the bottom of the slope and leaves the roof space higher up. If the soffit is a solid board with no opening anywhere along it, that air has nowhere to enter on a roof that relies on it.

So the question is never only about the board. It is about whether the roof above was built to take its air from the eaves.

If the answer is yes, the vent is part of the roof's design and not a decoration, and replacing the board without it changes how the roof behaves.

The figures Marley gives

Marley's cold roof ventilation page sets out different answers for different underlays. The underlay is the sheet that lies beneath the tiles or slates to catch any water that gets past them.

Eaves ventilation for a cold roof, as published by Marley
Underlay and roofEaves ventilation
HR underlay, pitch 15° or less25 mm, full eaves length
HR underlay, pitch more than 15°10 mm, full eaves length
Air-permeable underlay, sealed ceilingnormal eaves construction (3mm), on Marley's condition

Marley treats an HR underlay as one that is not vapour-permeable, which is why it needs the eaves opening. Its condition for the third row reads: "fortuitous ventilation at the eaves via normal eaves construction (3mm) is all that is required, provided the requirements of UKAS Third Party certification are fully met."

Pitch means the angle at which the slope rises, and the roofer measures it at the survey. Because the requirement changes at 15°, a shallow roof and a steeper one on the same house can need different amounts of opening, so the table is the starting point for the specification, not a substitute for it. Ask for the underlay and the pitch to be named in writing.

What to check when soffits are replaced

New boards should leave the roof working exactly as well as before. Before the old soffits come off, a survey looks at:

  • Which underlay the roof has, which can be seen from inside the loft with a torch.
  • Whether the existing soffit has vents or slots, and how long a stretch of eaves they cover.
  • Whether loft insulation has been pushed into the eaves and now blocks the air path.
  • The pitch of the roof, since the 25 mm and 10 mm figures change at 15°.

If the roof relies on eaves air, the replacement soffit has to keep the opening, so a plain solid board is the wrong choice. If the roof is of the air-permeable kind, a solid board may be acceptable, but the roofer should say why. Either way, the answer belongs in the written quote rather than in a verbal assurance, because it decides which boards are ordered.

A roofer who has looked at the underlay and the pitch can answer in one line. One who has not may simply order the board that matches the old one, which repeats any mistake already in the roof.

Before the old boards come off

Two other checks come ahead of the vent question. The first is asbestos. HSE's advice is: "If the building was built or refurbished before 2000, assume that there is asbestos in it." Its list of materials includes asbestos insulating board, or AIB, in white soffit panels at the eaves. For work on AIB, licensing applies if the risk assessment indicates that the job "will not be of short duration". An older soffit should therefore not be broken up as a first step. Our guide to asbestos in soffits explains what happens next.

The second is wildlife. The gap behind a soffit can shelter a nest or a bat roost, and our answer on birds nesting in the eaves sets out what the law protects.

The overall job of renewing the roof edge is covered under gutters, soffits and fascias.

Both checks come ahead of the vent question because they can stop work altogether. Agreeing the order of events at the survey avoids a halt halfway along a roof edge, and the written quote can say what happens if asbestos or wildlife turns up.

Related questions

How do I tell whether my loft relies on eaves ventilation?

Look at the underlay from inside the loft with a torch, or ask the roofer to check it at the survey. Marley says HR underlay needs the eaves ventilation. Where an air-permeable underlay is paired with a sealed ceiling, Marley's guidance differs. Either way, ask for the finding in writing.

Is a plain white soffit board without vents a problem?